APC APDU10452SM power distribution unit (PDU) 42 AC outlet(s) Black

APC APDU10452SM. PDU types: Metered, Switched, Type: Single-phase, Product color: Black. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler. Cable length: 70.9" (1.8 m). Management platform: NMC. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50/60 Hz
Manufacturer: APC
SKU: 6571066
Manufacturer part number: APDU10452SM
MSRP: $5,750.00
$5,518.00
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3PH, 17.3kW, 208V, 60A, 460P9, 42 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3PH, 17.3kW, 208V, 60A, 460P9, 42 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Products specifications
Attribute nameAttribute value
Height70.1"
Weight24.9 lbs
TypeSingle-phase
Load Capacity17300 VA
Number of phases3
Width2.2"
Depth2.95"
DisplayLCD
Cable Length70.9"
Design
PDU typesMetered, Switched
Technical details
Management platform3
Product colorBlack
Sustainability certificatesRoHS
Packaging data
Package width10.3"
Package depth5.2"
Package height78"
Package weight31.5 lbs
Other features
Nominal output voltage208 V
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports2
Power
Maximum power3
Maximum current60 A
Nominal input voltage208 V
AC input frequency50/60 Hz
Power protection featuresOverload
Operational conditions
Operating temperature (T-T)23 - 140 °F
Storage temperature (T-T)-25 - 65 °C
Non-operating altitude0 - 600000"
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"
*
*
*
Products specifications
Attribute nameAttribute value
Height70.1"
Weight24.9 lbs
TypeSingle-phase
Load Capacity17300 VA
Number of phases3
Width2.2"
Depth2.95"
DisplayLCD
Cable Length70.9"
Design
PDU typesMetered, Switched
Technical details
Management platform3
Product colorBlack
Sustainability certificatesRoHS
Packaging data
Package width10.3"
Package depth5.2"
Package height78"
Package weight31.5 lbs
Other features
Nominal output voltage208 V
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports2
Power
Maximum power3
Maximum current60 A
Nominal input voltage208 V
AC input frequency50/60 Hz
Power protection featuresOverload
Operational conditions
Operating temperature (T-T)23 - 140 °F
Storage temperature (T-T)-25 - 65 °C
Non-operating altitude0 - 600000"
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"
Product tags
  • (53806)