Tripp Lite SM3000RM2UTAA uninterruptible power supply (UPS) Line-Interactive 3 kVA 2250 W 9 AC outlet(s)

Tripp Lite SM3000RM2UTAA. UPS topology: Line-Interactive, Output power capacity: 3 kVA, Output power: 2250 W. Power plug: NEMA L5-30P, AC outlets quantity: 9 AC outlet(s). Typical backup time at full load: 3 min, Typical backup time at half load: 10 min, Battery recharge time: 5 h. Form factor: Rackmount, Product color: Black, Rack capacity: 2U. Width: 17.3" (439.9 mm), Depth: 19.5" (494.3 mm), Height: 3.43" (87.1 mm)
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 4011147
Manufacturer part number: SM3000RM2UTAA
UPC: 0037332184207
MSRP: $2,074.00
$1,500.77
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 98% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and slot for network management card options. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. PowerAlert UPS monitoring and auto shutdown software is available via free download. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules. - Federal Trade Agreements Act / TAA compliant for GSA schedule purchases - Tripp Lite SM3000RM2UTAA line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity (1600W maximum load with external battery packs) - Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V - NEMA L5-30P input plug; 8 NEMA 5-15/20R and 1 L5-30R output receptacles, Two independently switchable output load banks - Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages - High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emissions - Internal batteries offer 10 minutes at 50% load (1125W) and 3.5 minutes at 100% load (2250W) - Extended runtime is available with optional BP48V242UTAA (limit 1), BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible), BP48V60RT3UTAA (multi-pack compatible), and BP48V27-2US (multi-pack compatible) external battery packs (max output de-rates to 1600 watts with external batteries) - External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment - Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information - LCD interface also supports a number of advanced user setup and operating preferences - Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement - Built-in USB, RS-232 and slot for network management card options; Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD - HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert - Built-in Emergency Power Off (EPO) interface with cable Package Includes - SM3000RM2UTAA UPS System - USB, Serial & EPO cabling - 4-post rackmount installation kit - Owner's manual
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 98% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and slot for network management card options. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. PowerAlert UPS monitoring and auto shutdown software is available via free download. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules. - Federal Trade Agreements Act / TAA compliant for GSA schedule purchases - Tripp Lite SM3000RM2UTAA line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity (1600W maximum load with external battery packs) - Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V - NEMA L5-30P input plug; 8 NEMA 5-15/20R and 1 L5-30R output receptacles, Two independently switchable output load banks - Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages - High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emissions - Internal batteries offer 10 minutes at 50% load (1125W) and 3.5 minutes at 100% load (2250W) - Extended runtime is available with optional BP48V242UTAA (limit 1), BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible), BP48V60RT3UTAA (multi-pack compatible), and BP48V27-2US (multi-pack compatible) external battery packs (max output de-rates to 1600 watts with external batteries) - External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) - Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment - Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information - LCD interface also supports a number of advanced user setup and operating preferences - Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement - Built-in USB, RS-232 and slot for network management card options; Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD - HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert - Built-in Emergency Power Off (EPO) interface with cable Package Includes - SM3000RM2UTAA UPS System - USB, Serial & EPO cabling - 4-post rackmount installation kit - Owner's manual
Products specifications
Attribute nameAttribute value
Master (outer) case weight76.7 lbs
Output voltage regulation-14, +6 %
Output frequency regulation60 Hz
Weight62.8 lbs
Battery Recharge Time5 h
Rack mount kitY
Master (outer) case length21.7"
Master (outer) case width23.8"
Master (outer) case height8.4"
Country of OriginTaiwan
Width17.3"
Depth19.5"
Height3.43"
Emergency Power Off (EPO)Y
Input Frequency60 Hz
Cable Length122"
Display TypeLCD
UPS topologyLine-Interactive
EMI/RFI noise filteringY
Cold startY
Design
CertificationMeets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); TAA Compliant; Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Form factorRackmount
Technical details
Product colorBlack
Sustainability certificatesRoHS
Features
Surge energy rating570 J
Input operation voltage (min)110 V
Input operation voltage (max)120 V
Output operation voltage (min)110 V
Rack capacity2U
LED indicatorsY
Output power2250 W
Audible alarm(s)Y
Output operation voltage (max)120 V
Efficiency98 %
WaveformSine
Packaging data
Package weight76.7 lbs
Package widthHalogen
Package depth6.31 oz
Package height8.4"
Logistics data
Quantity per master (outer) case1 pc(s)
Packaging content
ManualY
Ports & interfaces
AC outlets quantity9 AC outlet(s)
USB 2.0 ports quantity1
Power plugNEMA L5-30P
Serial ports quantity1
Power
Maximum current24 A
Output power capacity3 kVA
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Battery
Typical backup time at full loadTower
Typical backup time at half load10 min
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Master (outer) case weight76.7 lbs
Output voltage regulation-14, +6 %
Output frequency regulation60 Hz
Weight62.8 lbs
Battery Recharge Time5 h
Rack mount kitY
Master (outer) case length21.7"
Master (outer) case width23.8"
Master (outer) case height8.4"
Country of OriginTaiwan
Width17.3"
Depth19.5"
Height3.43"
Emergency Power Off (EPO)Y
Input Frequency60 Hz
Cable Length122"
Display TypeLCD
UPS topologyLine-Interactive
EMI/RFI noise filteringY
Cold startY
Design
CertificationMeets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); TAA Compliant; Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Form factorRackmount
Technical details
Product colorBlack
Sustainability certificatesRoHS
Features
Surge energy rating570 J
Input operation voltage (min)110 V
Input operation voltage (max)120 V
Output operation voltage (min)110 V
Rack capacity2U
LED indicatorsY
Output power2250 W
Audible alarm(s)Y
Output operation voltage (max)120 V
Efficiency98 %
WaveformSine
Packaging data
Package weight76.7 lbs
Package widthHalogen
Package depth6.31 oz
Package height8.4"
Logistics data
Quantity per master (outer) case1 pc(s)
Packaging content
ManualY
Ports & interfaces
AC outlets quantity9 AC outlet(s)
USB 2.0 ports quantity1
Power plugNEMA L5-30P
Serial ports quantity1
Power
Maximum current24 A
Output power capacity3 kVA
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Battery
Typical backup time at full loadTower
Typical backup time at half load10 min
Hot-swap batteryY
Product tags