Alternate color or configuration shown
Server Technology C3WG36RL-0AJE2MT4 power distribution unit (PDU) 36 AC outlet(s) 0U Black
Server Technology C3WG36RL-0AJE2MT4. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, Power plug: C20 coupler. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 20 A, AC input frequency: 50/60 Hz. Compliance certificates: Electromagnetic Compatibility (EMC), Federal Communications Commission (FCC), UL
SKU:
6225327
Manufacturer part number:
C3WG36RL-0AJE2MT4
HDOT Cx Outlets
Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
Network Monitoring
Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Multi-Unit Linking & Cascading
Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
Multi-Color LCD
An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
Hot Swappable Controller
The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
RamLock Locking Outlets
A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
Environmental Monitoring
Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
Per-Inlet Power Sensing
PIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
Per-Outlet Power Sensing
POPS (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
Branch Current Monitoring
Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
Branch Circuit Protection
This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
Outlet Control
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
High Temperature Rating
This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
Flexible Mounting
Includes standard button mounts along with provisions for custom mounting brackets.