Server Technology C3W36RL-5CJE2MT2 power distribution unit (PDU) 36 AC outlet(s) 0U Black

Server Technology C3W36RL-5CJE2MT2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, Power plug: NEMA L22-30P. Monitoring: Current, Power, Voltage. Nominal input voltage: 415 V, Maximum current: 30 A, AC input frequency: 50/60 Hz. Compliance certificates: Electromagnetic Compatibility (EMC), Federal Communications Commission (FCC), UL
Manufacturer: SERVER TECHNOLOGY
SKU: 6331175
Manufacturer part number: C3W36RL-5CJE2MT2
$2,864.00
HDOT Cx Outlets

Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.

Network Monitoring

Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Multi-Unit Linking & Cascading

Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.

Multi-Color LCD

An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.

Hot Swappable Controller

The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.

RamLock Locking Outlets

A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.

Environmental Monitoring

Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.

Per-Inlet Power Sensing

PIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.

Branch Current Monitoring

Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.

Branch Circuit Protection

This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.

Outlet Control

On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.

High Temperature Rating

This product has been tested and approved for safe and reliable operation in 60 °C data center environments.

Flexible Mounting

Includes standard button mounts along with provisions for custom mounting brackets.

HDOT Cx Outlets

Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.

Network Monitoring

Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Multi-Unit Linking & Cascading

Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.

Multi-Color LCD

An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.

Hot Swappable Controller

The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.

RamLock Locking Outlets

A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.

Environmental Monitoring

Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.

Per-Inlet Power Sensing

PIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.

Branch Current Monitoring

Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.

Branch Circuit Protection

This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.

Outlet Control

On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.

High Temperature Rating

This product has been tested and approved for safe and reliable operation in 60 °C data center environments.

Flexible Mounting

Includes standard button mounts along with provisions for custom mounting brackets.

Products specifications

Attribute name Attribute value
Width 2.2"
Depth 2.52"
Height 70"
Mounting Vertical
Placement Indoor
Type Three-phase
Monitoring Current, Power, Voltage
Circuit breaker Yes
Compliance certificates Electromagnetic Compatibility (EMC), Federal Communications Commission (FCC), UL
Design
PDU types Monitored, Switched
Form factor Rackmount
Technical details
Product color Black
Features
Rack capacity 0U
Packaging content
Quantity per pack 1 pc(s)
Other features
Nominal output voltage 208 V
Rack mounting Yes
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
AC outlet types C13 coupler
Ethernet LAN (RJ-45) ports 4
USB ports quantity 2
Power plug NEMA L22-30P
Power
Maximum current 30 A
Nominal input voltage 415 V
AC input frequency 50/60 Hz
Maximum power 17300 W
Operational conditions
Operating temperature (T-T) 32 - 140 °F
Storage temperature (T-T) -40 - 85 °C
Operating relative humidity (H-H) 8 - 90 %
Storage relative humidity (H-H) 8 - 90 %
Operating altitude 0 - 78740.2"
Non-operating altitude 0 - 590551.2"
Display
Display LCD
*
*
*

Products specifications

Attribute name Attribute value
Width 2.2"
Depth 2.52"
Height 70"
Mounting Vertical
Placement Indoor
Type Three-phase
Monitoring Current, Power, Voltage
Circuit breaker Yes
Compliance certificates Electromagnetic Compatibility (EMC), Federal Communications Commission (FCC), UL
Design
PDU types Monitored, Switched
Form factor Rackmount
Technical details
Product color Black
Features
Rack capacity 0U
Packaging content
Quantity per pack 1 pc(s)
Other features
Nominal output voltage 208 V
Rack mounting Yes
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
AC outlet types C13 coupler
Ethernet LAN (RJ-45) ports 4
USB ports quantity 2
Power plug NEMA L22-30P
Power
Maximum current 30 A
Nominal input voltage 415 V
AC input frequency 50/60 Hz
Maximum power 17300 W
Operational conditions
Operating temperature (T-T) 32 - 140 °F
Storage temperature (T-T) -40 - 85 °C
Operating relative humidity (H-H) 8 - 90 %
Storage relative humidity (H-H) 8 - 90 %
Operating altitude 0 - 78740.2"
Non-operating altitude 0 - 590551.2"
Display
Display LCD