Server Technology C2WG36TE-5CAE2M66 power distribution unit (PDU) 36 AC outlet(s) 0U Black, Gray, White

Server Technology C2WG36TE-5CAE2M66. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, Power plug: NEMA L22-30P. Monitoring: Current, Power, Voltage. Nominal input voltage: 415 V, Maximum current: 30 A, AC input frequency: 50/60 Hz. Compliance certificates: Federal Communications Commission (FCC), cTUVus
Manufacturer: SERVER TECHNOLOGY
SKU: 5991508
Manufacturer part number: C2WG36TE-5CAE2M66
$3,982.00
Network Monitoring

The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Hot-Swap Network Card

Network access is ensured when power is lost to the Primary unit with backup power provided by the primary Expansion unit.

Star Multi-Linking

Linking allows access via a single primary PDU and up to 7 linked PDUs through a single IP address for more efficient power management.

Temperature/ Humidity Monitoring

Primary and Expansion (select products) units each support two external 10' (3m) Temperature/Humidity probes. Receive SNMP-based alerts and email notifications.

Auto-Flip Current Display

Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.

Per-Inlet Power Sensing

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.

Branch Current Monitoring

PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.

Branch Circuit Protection

PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

Alternating-Phase Outlets

3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.

High-Density Outlet Technology

The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention and UL94V-0 flame rating.

High Retention Locking Outlets

PRO2 receptacles have high retention and are compatible with P-Lock type power cords.

High Temperature Rating

This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.

Flexible Mounting

PRO2 includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).

Color Identification

Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

Cisco EnergyWise Compliant

PRO2 meets the requirements set forth by Cisco Systems, Inc. for its EnergyWise program for monitoring of device energy. EnergyWise is a registered trademark of Cisco Systems, Inc.

Network Monitoring

The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Hot-Swap Network Card

Network access is ensured when power is lost to the Primary unit with backup power provided by the primary Expansion unit.

Star Multi-Linking

Linking allows access via a single primary PDU and up to 7 linked PDUs through a single IP address for more efficient power management.

Temperature/ Humidity Monitoring

Primary and Expansion (select products) units each support two external 10' (3m) Temperature/Humidity probes. Receive SNMP-based alerts and email notifications.

Auto-Flip Current Display

Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.

Per-Inlet Power Sensing

Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.

Branch Current Monitoring

PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.

Branch Circuit Protection

PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

Alternating-Phase Outlets

3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.

High-Density Outlet Technology

The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention and UL94V-0 flame rating.

High Retention Locking Outlets

PRO2 receptacles have high retention and are compatible with P-Lock type power cords.

High Temperature Rating

This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.

Flexible Mounting

PRO2 includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).

Color Identification

Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

Cisco EnergyWise Compliant

PRO2 meets the requirements set forth by Cisco Systems, Inc. for its EnergyWise program for monitoring of device energy. EnergyWise is a registered trademark of Cisco Systems, Inc.

Products specifications

Attribute name Attribute value
Width 2.2"
Depth 2.52"
Height 70"
Mounting Vertical
Placement Indoor
Type Three-phase
Monitoring Current, Power, Voltage
Circuit breaker Yes
Compliance certificates Federal Communications Commission (FCC), cTUVus
Design
PDU types Monitored, Switched
Form factor Rackmount
Technical details
Product color Black, Gray, White
Features
Rack capacity 0U
Output voltage 208 V
On/off switch Yes
Packaging content
Quantity per pack 1 pc(s)
Other features
Rack mounting Yes
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
AC outlet types C13 coupler
Ethernet LAN (RJ-45) ports 1
Power plug NEMA L22-30P
Serial ports quantity 1
Power
Maximum current 30 A
Nominal input voltage 415 V
AC input frequency 50/60 Hz
Maximum power 17300 W
Operational conditions
Operating temperature (T-T) 32 - 140 °F
Storage temperature (T-T) -40 - 85 °C
Operating relative humidity (H-H) 8 - 90 %
Storage relative humidity (H-H) 8 - 90 %
Operating altitude 0 - 78740.2"
Non-operating altitude 0 - 590551.2"
Display
Display LED
*
*
*

Products specifications

Attribute name Attribute value
Width 2.2"
Depth 2.52"
Height 70"
Mounting Vertical
Placement Indoor
Type Three-phase
Monitoring Current, Power, Voltage
Circuit breaker Yes
Compliance certificates Federal Communications Commission (FCC), cTUVus
Design
PDU types Monitored, Switched
Form factor Rackmount
Technical details
Product color Black, Gray, White
Features
Rack capacity 0U
Output voltage 208 V
On/off switch Yes
Packaging content
Quantity per pack 1 pc(s)
Other features
Rack mounting Yes
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
AC outlet types C13 coupler
Ethernet LAN (RJ-45) ports 1
Power plug NEMA L22-30P
Serial ports quantity 1
Power
Maximum current 30 A
Nominal input voltage 415 V
AC input frequency 50/60 Hz
Maximum power 17300 W
Operational conditions
Operating temperature (T-T) 32 - 140 °F
Storage temperature (T-T) -40 - 85 °C
Operating relative humidity (H-H) 8 - 90 %
Storage relative humidity (H-H) 8 - 90 %
Operating altitude 0 - 78740.2"
Non-operating altitude 0 - 590551.2"
Display
Display LED