Family Description
The Server Technology PRO2 Smart/Switched POPS PDU provides control of outlet power(Switched only) and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS and POPS technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output (POPS only). These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart/Switched POPS “Master" PDU can be connected to as many as three (with optional module) PRO2 Smart/Switched POPS “Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Network Monitoring
The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Hot-Swap Network Card
Network access is ensured when power is lost to the Primary unit with backup power provided by the primary Expansion unit.
Star Multi-Linking
Linking allows access via a single primary PDU and up to 7 linked PDUs through a single IP address for more efficient power management.
Temperature/ Humidity Monitoring
Primary and Expansion (select products) units each support two external 10' (3m) Temperature/Humidity probes. Receive SNMP-based alerts and email notifications.
Products specifications
| Attribute name |
Attribute value |
|
Width
|
2.2" |
|
Depth
|
2.52" |
|
Height
|
80" |
|
Mounting
|
Vertical |
|
Placement
|
Indoor |
|
Type
|
Three-phase |
|
Monitoring
|
Current, Power, Voltage |
|
Circuit breaker
|
Yes |
|
Compliance certificates
|
Federal Communications Commission (FCC), UL, cTUVus |
|
PDU types
|
Monitored, Switched |
|
Form factor
|
Rackmount |
|
Product color
|
Black, Gray, White |
|
Rack capacity
|
0U |
|
Output voltage
|
208 V |
|
On/off switch
|
Yes |
|
Quantity per pack
|
1 pc(s) |
|
Rack mounting
|
Yes |
|
AC outlets quantity
|
48 AC outlet(s) |
|
AC outlet types
|
C13 coupler |
|
Ethernet LAN (RJ-45) ports
|
1 |
|
Power plug
|
NEMA L22-30P |
|
Serial ports quantity
|
1 |
|
Maximum current
|
30 A |
|
Nominal input voltage
|
415 V |
|
AC input frequency
|
50/60 Hz |
|
Maximum power
|
17300 W |
|
Operating temperature (T-T)
|
32 - 140 °F |
|
Storage temperature (T-T)
|
-40 - 85 °C |
|
Operating relative humidity (H-H)
|
8 - 90 % |
|
Storage relative humidity (H-H)
|
8 - 90 % |
|
Operating altitude
|
0 - 78740.2" |
|
Non-operating altitude
|
0 - 590551.2" |
|
Display
|
LED |