Raritan PX3-4666-E2 power distribution unit (PDU) 30 AC outlet(s) 0U Black

Raritan PX3-4666-E2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 50 A, AC input frequency: 50 - 60 Hz
Manufacturer: Raritan
SKU: 5895784
Manufacturer part number: PX3-4666-E2
$2,840.00
Monitored rack power distribution unit (0U [vertical], 12.6kVA, 30 outlets). INPUT: 208v (3-phase DELTA), 50a - CS8365C plug (3P4W); OUTPUT: 24@ C13 Locking, 6@ C19 Locking outlets; on 3@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 71mm x 1780mm (2.1in x 2.8in x 70.1in). Max Weight 7.3 kg. Maximum ambient temperature 60C at full load.

 

  • IEC Locking
  • Removable Controller
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
  • Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure
Monitored rack power distribution unit (0U [vertical], 12.6kVA, 30 outlets). INPUT: 208v (3-phase DELTA), 50a - CS8365C plug (3P4W); OUTPUT: 24@ C13 Locking, 6@ C19 Locking outlets; on 3@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 71mm x 1780mm (2.1in x 2.8in x 70.1in). Max Weight 7.3 kg. Maximum ambient temperature 60C at full load.

 

  • IEC Locking
  • Removable Controller
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
  • Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure

Products specifications

Attribute name Attribute value
Load Capacity 12600 VA
Block 1 output current 12 A
Block 2 output current 16 A
Height 70.1"
Weight 16.1 lbs
Mounting Vertical
Type Three-phase
Monitoring Current, Power, Voltage
Width 2.05"
Depth 2.8"
Display LCD
Cable Length 118.1"
Design
PDU types Monitored
Technical details
Product color Black
Features
Rack capacity 0U
Output voltage 208 - 240 V
On/off switch Y
Packaging data
Package width Universal
Package depth 8.82 oz
Package height 32 A
Package weight 22.3 lbs
Other features
Nominal output voltage 208 V
Ports & interfaces
Power plug Overload
AC outlets quantity 30 AC outlet(s)
USB ports quantity 3
AC outlet types C13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports 2
Power
Maximum current 50 A
Nominal input voltage 208 V
AC input frequency 50 - 60 Hz
Power protection features Overload
Operational conditions
Storage relative humidity (H-H) 220 - 240 V
Operating altitude 50 - 60 Hz
Storage temperature (T-T) -25 - 65 °C
Non-operating altitude 0 - 120000"
Operating temperature (T-T) 0 - 60 °C
Operating relative humidity (H-H) 0 - 85 %
Security
Security algorithms IEC 320
*
*
*

Products specifications

Attribute name Attribute value
Load Capacity 12600 VA
Block 1 output current 12 A
Block 2 output current 16 A
Height 70.1"
Weight 16.1 lbs
Mounting Vertical
Type Three-phase
Monitoring Current, Power, Voltage
Width 2.05"
Depth 2.8"
Display LCD
Cable Length 118.1"
Design
PDU types Monitored
Technical details
Product color Black
Features
Rack capacity 0U
Output voltage 208 - 240 V
On/off switch Y
Packaging data
Package width Universal
Package depth 8.82 oz
Package height 32 A
Package weight 22.3 lbs
Other features
Nominal output voltage 208 V
Ports & interfaces
Power plug Overload
AC outlets quantity 30 AC outlet(s)
USB ports quantity 3
AC outlet types C13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports 2
Power
Maximum current 50 A
Nominal input voltage 208 V
AC input frequency 50 - 60 Hz
Power protection features Overload
Operational conditions
Storage relative humidity (H-H) 220 - 240 V
Operating altitude 50 - 60 Hz
Storage temperature (T-T) -25 - 65 °C
Non-operating altitude 0 - 120000"
Operating temperature (T-T) 0 - 60 °C
Operating relative humidity (H-H) 0 - 85 %
Security
Security algorithms IEC 320
/* Added for Digitol */ /* End Added for Digitol */