The Eaton 9PX UPS provides energy-efficient power protection for small & medium Datacentres, IT rooms and Infrastructure. Delivering double conversion protection with 40% less energy usage and 28% more power 9PX is the perfect UPS for IT and Facility managers that are concerned by energy cost and are looking for next generation power protection solutions. - Online double conversion topology - Energy efficient (up to 95% in Online mode, 98% in high-efficiency mode, ENERGY STAR® qualified UPS) - Next-generation graphical LCD display (7 languages) - Provides more real power (watts) to protect more equipment with a 0.9 power factor - Parallel operation using HotSync technology (available in Q2 2013) - Maintenance ByPass available as standard (on HotSwap/BP version) - Energy metering - kWh values can be monitored using the LCD or Eaton’s Intelligent Power Software Suite - Compatible with Virtual environments (VMware, Hyper-V, Citrix Xen, Redhat)
Products specifications
Attribute name | Attribute value |
---|
Weight | 105.8 lbs |
Input Frequency | LCD |
Management card included | Y |
Depth | 27" |
Height | 5.12" |
Input current Total Harmonic Distortion (THD) | 5 % |
Rack mount kit | Y |
Harmonized System (HS) code | 85078000 |
Width | 17.3" |
Display Type | LCD |
Power factor | 0.9 |
Automatic battery test | Y |
UPS topology | Double-conversion (Online) |
Output frequency | 50/60 Hz |
Number of input phases | 1 |
Crest factor | 3:1 |
Certification | IEC/EN 62040-1, UL 1778, IEC/EN 62040 -2, FCC Class A, IEC/EN 62040-3 (Performance), CE, CB report (TUV), UL |
Form factor | Rackmount/Tower |
Product color | Black |
Sustainability certificates | ENERGY STAR |
Safety | IEC/EN 62040-1, UL 1778 |
Input operation voltage (min) | 50/60 Hz |
Input operation voltage (max) | 276 V |
Noise level | 45 dB |
Output voltage Total Harmonic Distortion (THD) | 2 % |
Waveform | Pure sine |
Rack capacity | 3U |
LED indicators | Y |
Output power | 5400 W |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Efficiency | 94 % |
Bundled software | Intelligent Power Software suite |
Nominal output voltage | 230 V |
AC outlet types | C13 coupler, C19 coupler, Terminal |
Interface | USB, RS232 |
Power plug | 50/60 Hz |
AC outlets quantity | 11 AC outlet(s) |
RS-232 ports | 1 |
USB 2.0 ports quantity | 1 |
USB port | Y |
Nominal input voltage | 230 V |
Output power capacity | 6 kVA |
Operating temperature (T-T) | 0 - 40 °C |
Typical backup time at half load | 11 min |
Battery technology | Sealed Lead Acid (VRLA) |
Hot-swap battery | Y |