CyberPower PDU44007 power distribution unit (PDU) 19 AC outlet(s) 2U Black

CyberPower PDU44007. PDU types: Switched, Monitored, Rack capacity: 2U, Type: Single-phase. AC outlets quantity: 19 AC outlet(s), AC outlet types: NEMA L6-30R, Power plug: NEMA L6-30P. LED indicators: Status, Selected, TX / RX, Link, Cable length: 118.1" (3 m). Monitoring: Current, Humidity, Temperature, Power, Voltage, Alarm, Supported network protocols: IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL,.... Nominal input voltage: 240 – 200 VAC, Maximum current: 30 A, AC input frequency: 50 Hz – 60
SKU: 6785394
Manufacturer part number: PDU44007
UPC: 0649532933938
MSRP: $2,000.00
$1,950.00
Product Overview
Ensure continued operation of critical devices with the CyberPower PDU44007 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.

The PDU44007 supports inputs between 200-240V and includes (16) IEC C13, (2) IEC C19, and (1) NEMA L6-30R outlets. Dual NEMA L6-30P power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications.

Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.

Automatic Transfer Switch
Dual power cords (A and B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources* to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.

Switchable Outlets
Provides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets.

Remote and Local Monitoring
Enables offsite and onsite tracking of PDU vitals.

Selectable Color LCD
Provides real-time meter status for current (amperes), input and output voltages, power consumption (kilowatts), and hardware/firmware versions. User selectable LCD background color allows for easy classification of PDU based on application. The LCD turns red when there is an alert.

Automatic Event Notifications
Reports immediate updates about power events via email, SMS text, or SNMP traps.

Upgradeable Firmware
Downloadable improvements (firmware updates) to programs that run the PDU.

Environmental Sensor Option
Supports optional environment sensor (ENVIROSENSOR) that allows for remote monitoring of rack temperature and humidity to ensure optimal operating environment.

Daisy-Chain Capability
Manages up to four PDUs with a single IP address.

Network-Grade Plugs and Outlets
Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.

Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.

 

  • Automatic Transfer Switch
  • Switchable Outlets
  • Remote and Local Monitoring
  • Selectable Color LCD
  • Automatic Event Notifications
Product Overview
Ensure continued operation of critical devices with the CyberPower PDU44007 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.

The PDU44007 supports inputs between 200-240V and includes (16) IEC C13, (2) IEC C19, and (1) NEMA L6-30R outlets. Dual NEMA L6-30P power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications.

Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.

Automatic Transfer Switch
Dual power cords (A and B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources* to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.

Switchable Outlets
Provides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets.

Remote and Local Monitoring
Enables offsite and onsite tracking of PDU vitals.

Selectable Color LCD
Provides real-time meter status for current (amperes), input and output voltages, power consumption (kilowatts), and hardware/firmware versions. User selectable LCD background color allows for easy classification of PDU based on application. The LCD turns red when there is an alert.

Automatic Event Notifications
Reports immediate updates about power events via email, SMS text, or SNMP traps.

Upgradeable Firmware
Downloadable improvements (firmware updates) to programs that run the PDU.

Environmental Sensor Option
Supports optional environment sensor (ENVIROSENSOR) that allows for remote monitoring of rack temperature and humidity to ensure optimal operating environment.

Daisy-Chain Capability
Manages up to four PDUs with a single IP address.

Network-Grade Plugs and Outlets
Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.

Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.

 

  • Automatic Transfer Switch
  • Switchable Outlets
  • Remote and Local Monitoring
  • Selectable Color LCD
  • Automatic Event Notifications

Products specifications

Attribute name Attribute value
Width 17"
Depth 8.46"
Height 3.5"
Weight 17.6 lbs
Type Single-phase
Monitoring Current, Humidity, Temperature, Power, Voltage, Alarm
Compliance certificates RoHS
Housing Material Metal
Cable Length 118.1"
Design
Certification UL62368 via cTUVus FCC Class A ICES-003: Issue 7
PDU types Switched, Monitored
Technical details
Product color Black
Features
Rack capacity 2U
LED indicators Status, Selected, TX / RX, Link
On/off switch Yes
Packaging data
Package width 21.5"
Package depth 16"
Package height 7"
Package weight 20.6 lbs
Other features
Nominal output voltage 240 – 200 VAC V
Ports & interfaces
AC outlets quantity 19 AC outlet(s)
AC outlet types NEMA L6-30R
Ethernet LAN (RJ-45) ports 2
USB ports quantity 1
Power plug NEMA L6-30P
Serial ports quantity 1
Power
Maximum current 30 A
Nominal input voltage 240 – 200 VAC V
AC input frequency 50 Hz – 60 Hz
Maximum input current per phase 30 A
Power protection features Overload
Operational conditions
Operating temperature (T-T) 32 - 113 °F
Storage temperature (T-T) -15 - 55 °C
Operating relative humidity (H-H) 0 - 95 %
Operating altitude 0 - 157480.3"
Non-operating altitude 0 - 590511.8"
Display
Display LCD
Protocols
Supported network protocols IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD
*
*
*

Products specifications

Attribute name Attribute value
Width 17"
Depth 8.46"
Height 3.5"
Weight 17.6 lbs
Type Single-phase
Monitoring Current, Humidity, Temperature, Power, Voltage, Alarm
Compliance certificates RoHS
Housing Material Metal
Cable Length 118.1"
Design
Certification UL62368 via cTUVus FCC Class A ICES-003: Issue 7
PDU types Switched, Monitored
Technical details
Product color Black
Features
Rack capacity 2U
LED indicators Status, Selected, TX / RX, Link
On/off switch Yes
Packaging data
Package width 21.5"
Package depth 16"
Package height 7"
Package weight 20.6 lbs
Other features
Nominal output voltage 240 – 200 VAC V
Ports & interfaces
AC outlets quantity 19 AC outlet(s)
AC outlet types NEMA L6-30R
Ethernet LAN (RJ-45) ports 2
USB ports quantity 1
Power plug NEMA L6-30P
Serial ports quantity 1
Power
Maximum current 30 A
Nominal input voltage 240 – 200 VAC V
AC input frequency 50 Hz – 60 Hz
Maximum input current per phase 30 A
Power protection features Overload
Operational conditions
Operating temperature (T-T) 32 - 113 °F
Storage temperature (T-T) -15 - 55 °C
Operating relative humidity (H-H) 0 - 95 %
Operating altitude 0 - 157480.3"
Non-operating altitude 0 - 590511.8"
Display
Display LCD
Protocols
Supported network protocols IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD