APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V uninterruptible power supply (UPS) 6400 W

APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V. Output power capacity: 8 kVA, Output power: 6400 W, Input frequency: 50/60 Hz. Battery technology: Sealed Lead Acid (VRLA), Typical backup time at full load: 5.9 min, Typical backup time at half load: 17 min. Certification: CSA,FCC Part 15 Class A,UL 1778. Weight: 392.9 lbs (178.2 kg). Interface: DB-9 RS-232, Smart-Slot, Output connections: 1x 4-wire 2x NEMA L14-30R 4x NEMA L5-20R, Dimensions (WxDxH): 18.6 x 27.1 x 22.5" (472 x 688 x 572 mm)
Manufacturer: APC
SKU: 1003434
Manufacturer part number: SYA8K8RMP
MSRP: $24,305.00
$20,278.89
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.

Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.

Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Products specifications
Attribute nameAttribute value
Weight392.9 lbs
Battery Recharge Time3 h
Emergency Power Off (EPO)Yes
Input Frequency50/60 Hz
Design
CertificationCSA,FCC Part 15 Class A,UL 1778
Features
Output power6400 W
Noise level62 dB
Audible alarm(s)Yes
Weight & dimensions
Dimensions (WxDxH)18.6 x 27.1 x 22.5"
Other features
Output connections1x 4-wire 2x NEMA L14-30R 4x NEMA L5-20R
Output voltage noteConfigurable for 120/208 or 120/240 output voltage
Ports & interfaces
Interface8 kVA
Power
Nominal input voltage208 V
Output power capacity8 kVA
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 45 °C
Battery
Typical backup time at full load5.9 min
Typical backup time at half load17 min
Battery technologySealed Lead Acid (VRLA)
*
*
*
Products specifications
Attribute nameAttribute value
Weight392.9 lbs
Battery Recharge Time3 h
Emergency Power Off (EPO)Yes
Input Frequency50/60 Hz
Design
CertificationCSA,FCC Part 15 Class A,UL 1778
Features
Output power6400 W
Noise level62 dB
Audible alarm(s)Yes
Weight & dimensions
Dimensions (WxDxH)18.6 x 27.1 x 22.5"
Other features
Output connections1x 4-wire 2x NEMA L14-30R 4x NEMA L5-20R
Output voltage noteConfigurable for 120/208 or 120/240 output voltage
Ports & interfaces
Interface8 kVA
Power
Nominal input voltage208 V
Output power capacity8 kVA
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 45 °C
Battery
Typical backup time at full load5.9 min
Typical backup time at half load17 min
Battery technologySealed Lead Acid (VRLA)