Availability Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Disconnected battery notification Warns when a battery is not available to provide backup power.
Manageability Network manageable Provides remote management of the UPS over the network. Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. LED status indicators Quickly understand unit and power status with visual indicators. Serial Connectivity Provides management of the UPS via a serial port. USB connectivity Provides management of the UPS via a USB port (not available on all models). Disconnected battery notification Warns when a battery is not available to provide backup power.
Serviceability User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Adaptability Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Safety Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Products specifications
Attribute name | Attribute value |
---|
Battery Capacity | 738 VAh |
Hold time (min) | 2 ms |
Weight | 82.2 lbs |
Depth | 26.3" |
Height | 3.35" |
Cable Length | 96.1" |
Rack mount kit | Y |
Hold time (max) | 10 ms |
SmartSlot | Y |
Width | 17" |
Automatic Voltage Regulation (AVR) | Y |
Battery Recharge Time | 3 h |
Emergency Power Off (EPO) | Y |
Input Frequency | 50/60 Hz |
Battery life (max) | 5 year(s) |
Automatic battery test | Y |
UPS topology | Line-Interactive |
Number of output IEC jumpers | 2 |
Output frequency regulation | 50/60 Hz |
Software CD | Y |
Auto-restart | Y |
Certification | C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, FCC Part 15 Class A, GOST, IRAM, UL 1778, VDE, REACH, PEP, EOLI |
Form factor | Rackmount/Tower |
Temperature sensor | 2 |
Product color | Black |
Sustainability certificates | RoHS |
Surge energy rating | Rackmount/Tower |
LED indicators | Battery replacement |
Output power | 2700 W |
Output operation voltage (min) | 208 V |
Efficiency | 98.5 % |
Rack capacity | 2U |
Noise level | 55 dB |
Audible alarm(s) | Y |
Output operation voltage (max) | 240 V |
Waveform | Sine |
Surge protection | Y |
Package depth | 34.2" |
Package width | 23.5" |
Package height | 3.35" |
Package weight | 100.1 lbs |
Quantity per pallet | 8 AC outlet(s) |
Cables included | RS-232 |
Manual | Y |
Nominal output voltage | 230 V |
AC outlets quantity | 9 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Power plug | C20 coupler |
Nominal input voltage | 230 V |
Output power capacity | 3 kVA |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 45 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Storage relative humidity (H-H) | 0 - 95 % |
Operating altitude | 0 - 118110.2" |
Non-operating altitude | 0 - 590551.2" |
Typical backup time at full load | 6.3 min |
Typical backup time at half load | 18 min |
Battery technology | Sealed Lead Acid (VRLA) |
Hot-swap battery | Y |