APC Galaxy VS Double-conversion (Online) 40 kVA 40000 W

APC Galaxy VS. UPS topology: Double-conversion (Online), Output power capacity: 40 kVA, Output power: 40000 W. Battery technology: Sealed Lead Acid (VRLA), Battery voltage: 480 V. Form factor: Tower, Product color: White, Display type: LCD. Width: 20.5" (521 mm), Depth: 33.3" (847 mm), Height: 58.5" (1485 mm)
Manufacturer: APC
SKU: 6595034
Manufacturer part number: GVSUPS40K0B4HS
UPC: 0731304410065
MSRP: $31,665.00
$26,187.35
Highly efficient, easy-to-deploy 40kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. This UPS is for up to 4 smart modular high capacity battery strings, but is supplied without batteries, so you can easily customize the battery runtime. Includes 5x8 start-up service. Compatible with Schneider Electric's lithium ion battery solution Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Built-in backfeed protection Full built-in backfeed contactor ensures that no electricity is sent back to the grid. Parallel-redundant capable Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy Parallel-capacity capable Increases total power capacity by using multiple uninterruptible power supplies simultaneously. Flexible DC bus Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries. Embedded Network Management Card Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU. Compact UPS High-density technology and full front access make this UPS a footprint saver well suited for confined spaces. High efficiency in double conversion mode Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source. ECOnversion mode Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation. Robust operation No power derating in kW up to 40 degrees C or 104 degrees F. Input Power Factor Correction Minimizes installation costs by enabling the use of smaller generators and cabling. Wide input voltage range Designed for harsh electrical environments to save battery life. Modular UPS design Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules. Multiple levels of service offers With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you. EcoStruxure IT Expert From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. Front-access servicing Simplifies installation and UPS maintenance while minimizing space requirements.
Highly efficient, easy-to-deploy 40kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. This UPS is for up to 4 smart modular high capacity battery strings, but is supplied without batteries, so you can easily customize the battery runtime. Includes 5x8 start-up service. Compatible with Schneider Electric's lithium ion battery solution Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Built-in backfeed protection Full built-in backfeed contactor ensures that no electricity is sent back to the grid. Parallel-redundant capable Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy Parallel-capacity capable Increases total power capacity by using multiple uninterruptible power supplies simultaneously. Flexible DC bus Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries. Embedded Network Management Card Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU. Compact UPS High-density technology and full front access make this UPS a footprint saver well suited for confined spaces. High efficiency in double conversion mode Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source. ECOnversion mode Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation. Robust operation No power derating in kW up to 40 degrees C or 104 degrees F. Input Power Factor Correction Minimizes installation costs by enabling the use of smaller generators and cabling. Wide input voltage range Designed for harsh electrical environments to save battery life. Modular UPS design Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules. Multiple levels of service offers With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you. EcoStruxure IT Expert From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. Front-access servicing Simplifies installation and UPS maintenance while minimizing space requirements.
Products specifications
Attribute nameAttribute value
Height58.5"
Width20.5"
Depth33.3"
Input Frequency40/70 Hz
Input current Total Harmonic Distortion (THD)3 %
Input power factor0.99
ECO modeY
Output voltage regulation1 %
Number of input phases3
Harmonized System (HS) code85078000
Number of output phases3
Weight440.9 lbs
Display TypeLCD
UPS topologyDouble-conversion (Online)
Output frequency50/60 Hz
Crest factor2.5:1
Design
CertificationIEC 62040-1-1, IEC 62040-2, OSHPD
Form factorTower
Technical details
Product colorWhite
Features
Input operation voltage (min)340 V
Input operation voltage (max)460 V
Output power40000 W
Noise level65 dB
Output operation voltage (max)415 V
Output voltage Total Harmonic Distortion (THD)3 %
Audible alarm(s)Y
Output operation voltage (min)380 V
WaveformSine
International Protection (IP) codeIP20
Packaging data
Package widthMultifunctional
Package height66.1"
Package weight440.9 lbs
Package depth39"
Packaging content
ManualY
Power
Maximum current72 A
Output power capacity40 kVA
Operational conditions
Storage temperature (T-T)-15 - 40 °C
Non-operating altitude0 - 120000"
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 39598.4"
Battery
Battery technologySealed Lead Acid (VRLA)
Battery voltage480 V
*
*
*
Products specifications
Attribute nameAttribute value
Height58.5"
Width20.5"
Depth33.3"
Input Frequency40/70 Hz
Input current Total Harmonic Distortion (THD)3 %
Input power factor0.99
ECO modeY
Output voltage regulation1 %
Number of input phases3
Harmonized System (HS) code85078000
Number of output phases3
Weight440.9 lbs
Display TypeLCD
UPS topologyDouble-conversion (Online)
Output frequency50/60 Hz
Crest factor2.5:1
Design
CertificationIEC 62040-1-1, IEC 62040-2, OSHPD
Form factorTower
Technical details
Product colorWhite
Features
Input operation voltage (min)340 V
Input operation voltage (max)460 V
Output power40000 W
Noise level65 dB
Output operation voltage (max)415 V
Output voltage Total Harmonic Distortion (THD)3 %
Audible alarm(s)Y
Output operation voltage (min)380 V
WaveformSine
International Protection (IP) codeIP20
Packaging data
Package widthMultifunctional
Package height66.1"
Package weight440.9 lbs
Package depth39"
Packaging content
ManualY
Power
Maximum current72 A
Output power capacity40 kVA
Operational conditions
Storage temperature (T-T)-15 - 40 °C
Non-operating altitude0 - 120000"
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 39598.4"
Battery
Battery technologySealed Lead Acid (VRLA)
Battery voltage480 V
Product tags