APC APDU10351SW power distribution unit (PDU) 24 AC outlet(s) 0U Black

APC APDU10351SW. PDU types: Switched, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 24 AC outlet(s). Certification: CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1. Nominal input voltage: 200 - 240 V, Maximum current: 30 A, AC input frequency: 50/60 Hz. Width: 2.2" (56 mm), Depth: 2.95" (75 mm), Height: 70.1" (1780 mm)
Manufacturer: APC
SKU: 6571069
Manufacturer part number: APDU10351SW
MSRP: $3,590.00
$3,445.89
APC NetShelter Rack PDU Advanced, Switched, 8.6kW, 3PH, 208V, 30A, L21-30P, 48 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.

 

  • Maximum Outlet Density All models include 40, 42, or 48 outlets
  • Space Saving
  • High Power Capacity Models now available to provide up to 34.6kW
  • APC Locking Power Cord Compatible Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet
  • Circuit Breaker Monitoring
  • Alternating Phase
  • 60ºC (140ºF) Operating Temperature
  • Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU
  • Hydraulic Magnetic Circuit Breakers
  • Live Swap Network Management Card
  • Environmental Sensor Support
  • Color LCD Display
  • Dual Network Ports
APC NetShelter Rack PDU Advanced, Switched, 8.6kW, 3PH, 208V, 30A, L21-30P, 48 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.

 

  • Maximum Outlet Density All models include 40, 42, or 48 outlets
  • Space Saving
  • High Power Capacity Models now available to provide up to 34.6kW
  • APC Locking Power Cord Compatible Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet
  • Circuit Breaker Monitoring
  • Alternating Phase
  • 60ºC (140ºF) Operating Temperature
  • Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU
  • Hydraulic Magnetic Circuit Breakers
  • Live Swap Network Management Card
  • Environmental Sensor Support
  • Color LCD Display
  • Dual Network Ports
Products specifications
Attribute nameAttribute value
Width71.9"
DepthSingle-phase
HeightC13 coupler, C15 coupler, C19 coupler, C21 coupler
Weight20.7 lbs
MountingVertical
TypeSingle-phase
Load Capacity8600 VA
Daisy chainY
DisplayLCD
Design
CertificationIEC 60309
PDU typesSwitched
Technical details
Product colorBlack
Features
Rack capacity0U
On/off switchN
Packaging data
Package depth4.57"
Package height78"
Package width8.19"
Package weight27.3 lbs
Other features
Nominal output voltage208 V
Ports & interfaces
AC outlets quantity24 AC outlet(s)
Power
Maximum total current draw per phaseY
Nominal input voltage200 - 240 V
Maximum input current per phase30 A
Maximum current30 A
AC input frequency50/60 Hz
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Non-operating altitude0 - 600000"
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"
*
*
*
Products specifications
Attribute nameAttribute value
Width71.9"
DepthSingle-phase
HeightC13 coupler, C15 coupler, C19 coupler, C21 coupler
Weight20.7 lbs
MountingVertical
TypeSingle-phase
Load Capacity8600 VA
Daisy chainY
DisplayLCD
Design
CertificationIEC 60309
PDU typesSwitched
Technical details
Product colorBlack
Features
Rack capacity0U
On/off switchN
Packaging data
Package depth4.57"
Package height78"
Package width8.19"
Package weight27.3 lbs
Other features
Nominal output voltage208 V
Ports & interfaces
AC outlets quantity24 AC outlet(s)
Power
Maximum total current draw per phaseY
Nominal input voltage200 - 240 V
Maximum input current per phase30 A
Maximum current30 A
AC input frequency50/60 Hz
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Non-operating altitude0 - 600000"
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"